The Pulse Air Pressure Breast Pump is a wearable electric breast pump for strong-suction product ranges requiring defined vacuum output, adjustable suction, and cordless operation. It combines a 280–300 mmHg vacuum range, 12 suction levels, and 4 operating modes in a compact wearable format.
The pump integrates the air pressure motor, control system, rechargeable battery, silicone flange, and 180 ml milk collection bottle into a 126 × 113 × 69 mm unit.
Product Positioning
Strong-Suction Configuration: The 280–300 mmHg vacuum range provides a clear reference for product lines requiring a defined strong-suction specification.
Wearable Format: The pump, battery, controls, flange, and collection bottle are integrated into one unit, keeping the operating structure compact.
Pulse Air Pressure: The pulse air pressure motor generates the pumping vacuum. A silicone diaphragm separates the pumping mechanism from the milk path.
Key Specifications
|
Parameter |
Specification |
|
Product Type |
Wearable Electric Breast Pump |
|
Vacuum Range |
280–300 mmHg |
|
Suction Adjustment |
12 Levels |
|
Operating Modes |
4 |
|
Milk Bottle Capacity |
180 ml |
|
Flange Size |
27 mm / 24 mm |
|
Battery Capacity |
1200 mAh × 2 |
|
Usage Time |
Approx. 90 Minutes |
|
Charging Time |
Approx. 2.5 Hours |
|
Power Input |
DC 5V / 1A |
|
Rated Power |
4W |
|
Product Size |
126 × 113 × 69 mm |
|
Net Weight |
Approx. 240 g |
|
Auto Shut-Off |
30 Minutes |
Pumping Control
12-Level Adjustment: Twelve suction levels provide a defined adjustment range for products requiring variable vacuum intensity.
Four Operating Modes: The four operating modes provide different pumping patterns within the same control system, allowing the configuration to cover multiple pumping stages.
Vacuum Specification: The 280–300 mmHg range provides a measurable specification for technical comparison, product documentation, and configuration review.
Air Pressure System
Pulse Air Pressure Motor: The pulse air pressure motor generates the vacuum through controlled air pressure changes within the pumping system.
Silicone Diaphragm: The silicone diaphragm separates the pumping mechanism from the milk collection path and forms part of the fluid-control structure.
Backflow Protection: The diaphragm structure helps prevent milk from reaching the motor assembly, keeping the milk path separated from the drive section.
Battery & Power
Battery Configuration: The pump uses two 1200 mAh rechargeable batteries for cordless operation.
Operating Time: The specified operating time is approximately 90 minutes, with an approximate 2.5-hour charging time.
Power Input: Charging uses DC 5V / 1A, while rated power is 4W. These values provide fixed references for electrical specifications and product documentation.
Milk Collection Configuration
180 ml Capacity
The integrated milk bottle provides 180 ml collection capacity within the wearable structure.
Flange Options
The configuration includes 27 mm and 24 mm flange sizes for different product configurations.
Product Construction
Compact Dimensions: The complete unit measures 126 × 113 × 69 mm, covering the integrated pumping, control, battery, flange, and collection structure.
Net Weight: The pump weighs approximately 240 g, providing a defined reference for product packaging and portable-use specifications.
Auto Shut-Off: The automatic shut-off time is 30 minutes, establishing a fixed operating cycle for the control system.
Application Fit
Daily Pumping: The adjustable vacuum, multiple operating modes, and integrated bottle configuration fit regular pumping routines.
Workplace Use: The cordless structure reduces the need for an external pump unit during portable use and keeps the operating components within the wearable format.
Portable Product Lines: The model fits product ranges where vacuum output, battery operation, bottle capacity, dimensions, and weight are key selection parameters.
Selection Considerations
Vacuum Requirement: The 280–300 mmHg range is relevant when a product specification requires defined strong-suction output.
Control Requirement: The 12 suction levels and 4 operating modes provide measurable control parameters for product configuration.
Size Requirement: The 126 × 113 × 69 mm dimensions and approximately 240 g net weight provide fixed references for packaging, storage, and product development.
Quality & Production Considerations
Component Configuration
The main assembly consists of the pulse air pressure motor, silicone diaphragm, rechargeable batteries, control system, flange, and milk collection bottle.
Specification Control
Key production specifications include vacuum range, suction levels, operating modes, battery capacity, bottle capacity, dimensions, weight, power input, and charging time.
Product Documentation
Technical documentation can be organized around operating parameters, electrical specifications, component configuration, dimensions, and included accessories.
OEM & Product Configuration
Private-Label Programs
The product platform can be configured for private-label wearable breast pump ranges requiring defined suction, battery, collection, and dimensional specifications.
Configuration Review
Final configuration can cover flange size, color, packaging, labeling, accessories, and other product-level requirements.
Technical Matching
Before production, the required vacuum range, operating modes, battery configuration, bottle capacity, dimensions, and accessory list should be confirmed against the final specification.
FAQ

